Diagnostics of steam turbine rotors
              Figure shows the testing results of the average pressure rotor of one of the 
                turbines K-300-240 LMZ mounted on the Konakovo hydroelectric power station. It 
                is seen on figure that maximum field Нр change is registered on the disk hub №28 
                between sides of steam inlet and outlet. The obtained result according to 
                applying method witnesses about disk № 28 operation in conditions of significant 
                axial vibrations. 
                
              Fig.1. The testing results of the turbine 
                rotors.  |